Model Image GTD9X1002-WWWVV-TW, ITE / Medical Power Supply/Class 2/Household Power Supply,  60601-1-4th Ed. , Desktop/External, DC-DC, , Input Rating: 9-36VDC, Lead Wire, see Blades/Cord Included for description, Output Rating: 100 Watts, Power rating with convection cooling (W) , 15V in 0.1V increments, Approvals: Double Insulation; EAC; PSE; China RoHS; Ukraine; VCCI; WEEE; RoHS;
Information
Model NumberGTD9X1002-WWWVV-TW
DescriptionGTD9X1002-WWWVV-TW, ITE / Medical Power Supply/Class 2/Household Power Supply, 60601-1-4th Ed. , Desktop/External, DC-DC, , Input Rating: 9-36VDC, Lead Wire, see Blades/Cord Included for description, Output Rating: 100 Watts, Power rating with convection cooling (W) , 15V in 0.1V increments, Approvals: Double Insulation; EAC; PSE; China RoHS; Ukraine; VCCI; WEEE; RoHS;
Agency Documents
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0O0c00000QD1HqEAL
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0O0c00000QD1HqEAL
CE EC-Declaration for Householdhttps://globtek.secure.force.com/models/ec_declaration?id=a0O0c00000QD1HqEAL
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O0c00000QD1HqEAL
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O0c00000QD1HqEAL
UKCA-Declaration for Householdhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O0c00000QD1HqEAL
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0O0c00000QD1HqEAL
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0O0c00000QD1HqEAL
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeDesktop/External
TechnologyDC-DC
CategoryITE / Medical Power Supply/Class 2/Household Power Supply
Input Voltage Range (V)9-36VDC
Max Input Current (A)17.5 A
Max Output Power Rating (W)100
Output Voltage Range (V)15
Efficiency
Ingress ProtectionIP43
Size (mm)149.4 x 62.6 x 33.5
EnclosureUser-added image

 
Rating Table
Preferred ratings shown below.
Custom output voltages available in 0.1V increment from the minimum voltage listed to the maximum voltage listed; contact sales.
Model Number (Final ordering #/Part No to be defined) VoltageAmps (A)Watts (W) RFQ
GTD9X1002-6015-TW* 15460
GTD9X1002-WWWVV-TW-XXXXCUSTOM CUSTOMCUSTOM
* (Final ordering #/Part No to be defined)
Specifications

Input

Input Range9 - 36VDC
Input Current17.5A (max) @ 9VDC & peak output current rating
No Load Input Power:< 0.5W @ 9-16VDC, < 1.0W @ 16-28VDC, < 1.5W @ 28-36VDC
Efficiency:> 77% @ 9VDC, > 83% @ 12VDC, > 87% @ 24VDC, > 88% @ 36VDC (100W load)
Inrush Current:< 1.5A (peak) @ 14VDC, exceeds DO-160G, Section 16.7.5.2

Output

Output Current:4.0A (nominal), 8.0A (peak)
Output Voltage:15.0V ± 1.5% @ no load
Turn-on Delay:< 2 seconds
Output Regulation+1.5% / -4% max. (14.40 - 15.23V) (measured at the output connector)
Line Regulation:± 0.1 % typ.  (measured at the output connector)
Ripple:150mV max. (using a 10µF low-ESR electrolytic cap + 0.1µF ceramic cap, measured @ 20MHz BW, at the output connector)
Transient Response (Step Load):10% max. deviation, 2ms max. recovery time (with 100W load step)
Transient Response
(Load Dump):
5% max. deviation, 100ms max. recovery time (with 100W load dump)

Protections

Input Protection:Input line fusing
Reverse polarity protection
Input Under-Voltage Protection:Shut down @ 7.3V, Restore @ 8.9V (nom.)
Input Over-Voltage Protection:Shut down @ 40.3V, Restore @ 38.4V (nom.)
Output Over-Voltage Protection:110 - 130%, Latching, cycle AC to reset
Output Over-Current Protection:115 - 150%, Auto-recovery
Output Short-Circuit Protection:Auto-recovery
Over-Temperature Protection:Auto-recovery, with back-up one-shot thermal fuse

Environmental

MTBF:> 750,000 hours @ 50°C ambient (Demonstrated + Telcordia SR-332, Issue 3)
> 1,500,000 hours @ 25°C ambient (Telcordia SR-332, Issue 3)
Operating Temperature:-10°C to 50°C (nominal load)
Storage Temperature:-40°C to 80°C
Humidity:0% to 95% relative humidity, non-condensing
Altitude5000m
Cooling:Convection
Shock:End use handling: Half-sine, <3ms duration, 1.65m/s, 3 shocks per face
Transportation simulation: Trapezoid, 60G acceleration, 5.75m/sec, 3 shocks per face
General shock: Half-sine, 100G acceleration, 6ms duration, 3 shocks per face
Vibration:ISO 80601-2-61, Clause 201-15.3.5.101.1b
DO-160G, Section 8, Procedure 8.8, Category U, Zone G
Bump:EN1789, Clause 6.4.1
Drop:EN1789, Clause 6.4.2
Ingress ProtectionIP43
RoHS:Complies with EU 2011/65/EU and China SJ/T 11363-2006

Safety

Applicable Standards:General medical: EN 60601-1
Home healthcare: EN 60601-1-11
EMS: EN 60601-1-12
Dielectric Withstand Voltage (Hi-Pot):4300VDC from input to output,  1 minute
4300VDC from input to case, 1 minute
500VAC from output to case, 1 mnute
Touch Current:NC: 8µA max.
SFC: 40µA max.
Means of Protection:2 x MOPP
Output Isolation:Class II

EMC

Applicable Standards:Aviation: RTCA DO-160G
Medical: EN 60601-1-2, 4th edition
Emissions: EN55032, EN61000-6-3, EN61000-6-4
Immunity: EN55024, EN61000-6-1, EN61000-6-2
Conducted Emissions:EN55032, Class B
DO-160G, Category M
(measured with resistive load)
Radiated Emissions:EN55032, Class B
DO-160G, Category M
(measured with resistive load)
Input Voltage Interruptions, Dips, Surges and SpikesDO-160G, Section 16.6.1.3, Category Z (Momentary interruption)
DO-160G, Section 16.6.1.4, Category Z (Normal surge)
DO-160G, Section 16.6.2.4, Category Z (Abnormal surge)
DO-160G, Section 17, Category B (Spikes)
Electrostatic Discharge (ESD) Immunity:EN61000-4-2, 8KV contact discharge, 15KV air discharge, Criterion A
Radiated RF Immunity:EN61000-4-3, 20V/m @ 80MHz - 2.7GHz, 80% 1KHz AM, 80% 5Hz AM, Criterion A
EFT/Burst Immunity:EN61000-4-4, 2KV/100KHz., Criterion A
Conducted RF Immunity:EN61000-4-6, 3VRMS & 6VRMS (ISM & Amateur bands), 80% 1KHz AM, Criterion A

Enclosure

Housing:High impact plastic, 94V0 polycarbonate, non-vented
Markings:Adhesive backed label or laser engraving
Derating CurveUser-added image
 
Qty (ea.)/Carton60
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box Color
Master Carton Size (mm)480 x 450 x 205
Gross Weight (kg)15.2
Label Width (mm)110.00
Label Height (mm)50.00
Input Configuration
DescriptionLead Wire, see Blades/Cord Included for descriptionUser-added image
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug) C Type (Coaxial 5.5x2.1mm plug) K Type (Coaxial 3.5x1.3mm plug) LL Type (5.5x2.5mm Locking 760k type) CL Type (5.5x2.1mm Locking S761k type) Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P) YL4 Type (KPPX-4P) EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) MSB Type (Micro USB) Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals
LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php

 
User-added image  Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added imageUKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request
160476315.04.004 Pin Plug (Caton P/N 32271-100) +back-shell (P/N 32014-100) or equivalent
82770315.04.004 Pin Plug (Caton P/N 32271-100) +back-shell (P/N 32014-100) or equivalent
What is an IEC 60601-1 medical grade rated power supply AC adapter?

An IEC 60601-1-2 medical grade rated power supply AC adapter converts input line voltage from the wall to a lower voltage, typically DC, which is used to operate and end use piece of medical equipment. IEC 60601-1-2 medical grade power supply AC adapters are typically housed in a plastic enclosure and are available with both 2 and 3 prong input options. power supplies are also available as open frame for use inside of medical equipment. These AC to DC converters are designed in accordance with international medical standards and provide for compliance with certain aspects of them which differs from generic information and communication technology equipment power supplies.

Why is my medical grade IEC 60601-1 power supply certified to IEC 60601-1 3rd Edition while the latest standard is IEC 60601-1 4th Edition?
IEC 60601-1 has different sections in specifications for safety and EMI/EMC. The latest revision of the safety portion of  IEC 60601-1 is 3rd Edition while for EMI/EMC the latest revision is 60601-1-2, 4th Ed. 

What is the effective date of 60601-1-2, 4th Ed?
60601-1-2, 4th Ed. was effective on December 31, 2018.

What's the difference between an IEC 60950-1 and IEC 60601-1 medical grade rated power supply?

IEC 60950-1 and IEC 60601-1-2 power supplies are both AC to DC converters and may be either internal or external but are designed to different specifications to match the end system specifications. While the basic performance behaviors are similar such as input and output voltages and mechanical configurations, there are many differences as well. Some of the key differences are that medical IEC 60601 medical grade AC to DC adapters are able to withstand a higher dielectric withstand voltage and must have lower leakage current.  There are many other differences and also considerations to consider depending on the end use application.  

What MOOP and MOPP?
Medical devices must incorporate one or more Means of Protection (MOPs) to isolate patients and operators from the risks of electrocution. A Means of Protection (MOPs)  can be safety insulation, a protective earth, a defined creepage distance, or an air gap or other protective impedance. These can be used in various combinations. IEC 60601-1 3rd edition differentiates between the risk to patients and the risk to operators. A MOP can therefore be classified as Means of Patient Protection (MOPP) or a Means of Operator Protection (MOOP). The main difference between one MOOP and one MOPP is primarily one of permissible creepage distance. Both requirements are satisfied using Basic insulation. To achieve 2 x MOPP qualification the isolation test is particularly demanding at 4000 Vac and the creepage distance of 8mm is twice that required for one MOPP. 

What is a BF and CF rated an IEC 60601-1-2 medical grade rated power supply AC adapter and what is the difference?

Medical grade power supplies and AC to DC adapters are categorized into one of three applied parts types: body type (B), body floating type (BF), and cardiac floating type (CF). These applied parts require specific attributes such as isolation voltage, creepage and leakage current. Floating refers to an ungrounded power supply, Class II, that is not referenced to another output and is fully isolated. Type B refers to devices that operate within the patient's vicinity, as described in IEC 60601-1 as six feet around a patient's chair or bed and do not touch the patient electronically and are grounded. These devices include operating room lighting, hospital carts and beds, automated dispensers of medication and supplies, and diagnostic equipment like x-ray machines. Type BF devices deliver electrical energy signals to or from the patient such as electrosurgical devices, endoscopes, and electrical vital sign monitors like thermometers. Type CF devices are similar to BF, except they supply power to devices connected to the heart, such as a defibrillator, external pacemaker or intracardiac ECG electrodes and Type CF requires a higher degree of protection against electrical shock than BF types.  
 

What is an external desktop AC-DC Adapter?

External desktop AC-DC adapters are also known as AC Adaptors or AC-DC converters and are a type of external power supply. Some electrical appliances require power but lack the internal components to derive the required voltage and power from mains power. This is where an AC adapter is used to convert the AC current into DC voltage

Request Info